Pressure switches with adjustable differential
(Type G)
When setting the pressure switch, adjust the setting point on falling pressure
first, then the setting point on rising pressure.
• Setting point on falling pressure
The setting point on falling pressure is set by adjusting range-nut 1.
• Setting point on rising pressure
The setting point on rising pressure is set by adjusting range-nut 2.